Viper-008 ( 8*TX, M12 ) EN50155

WESTERMO  Endüstriyel 8 Port Yönetilemez Fast Ethernet Switcht ( 8×10/100-TX, M12 Konnektörlü )

Viper serisi Endüstriyel Ethernet switchlerin genel özelliklerinden bazıları;

· 8 adet 10 / 100 Mbps rugged M12 konnektör
· Büyük networklerde FRNT ( Fast Recovery of Network Topology ) Ring yedeklemesi ile maksimum 20ms’de alternatif yol yedeklemesi
· SNMP, VLAN, QoS, IGMP Snooping, HoL, STP / RSTP desteği
· Kolay konfügürasyon ve üst seviye diagnostic
· Demiryolu araçları için bir standart olan EN 50155 onaylı
· Geniş çalışma sıcaklık aralığı ( – 40 / + 70 )
· 800.000 saatden fazla MTBF değeri
· IP65 robust çok ince metal kaplama
· Geniş DC enerji besleme aralığı ( 24-110V)
· Hareketli parça ve elektrolitik kapasite içermemektedir.
· Yüksek vibrasyona dayanıklı

Viper-008

Product description
Status Active
Article number 3641–0340
Ports 8 x 10/100BaseTX, M12 contact
Description Ultra slim M12 switch platform
Warranty period 5 Years
Reliability prediction
MTBF, operating Ground Benign:
150 years @ 20ºC
147 years @ 40ºC
135 years @ 60ºC
Ground Mobile:
9,87 years @ 20ºC
9,85 years @ 40ºC
9,79 years @ 60ºC
Ground Fix:
28,54 years @ 20ºC
28,43 years @ 40ºC
27,95 years @ 60ºC
Service life, operating Operating, 10 year
EMC (Electromagnetic Compatibility)
EN 61000-6-1 Immunity residential environments
EN 61000-6-2 Immunity industrial environments
EN 55024 Immunity IT equipment
EN 55022 Emission IT equipment
EN 61000-6-3 Emission residential environments
EN 61000-6-4 Emission industrial environments
EN-50155 Railway applications – Electronic equipment used on rolling stock
EN-50121-3-2 Railway applications – EMC: Rolling stock – Apparatus
FCC part 15 Class B
EN 50121-4 Railway signalling and telecommunications apparatus
IEC 62236-4 Railway signalling and telecommunications apparatus
EMC specifications
EN 61000-4-2, ESD Enclosure contact, ± 6 kV (crit A)
Enclosure air, ± 8 kV (crit A)
IEC 61000-4-3, RF field AM modulated Enclosure:
20 V/m 80% AM (1 kHz)
80 – 2500 MHz (crit A)
EN 61000-4-4, fast transients Ethernet ports, ± 2 kV (crit A)
Power port, ± 2 kV (crit A)
Earth port, ± 2 kV (crit A)
EN 61000-4-5, surge Fault port, ± 2 kV line to earth (crit A)
Ethernet ports, ± 2 kV line to earth (crit A)
Ethernet ports, ± 2 kV line to earth (crit A)
EN 61000-4-6, conducted RF immunity Ethernet ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz (crit A)
Power port, 10 V 80% AM (1 kHz), 0.15 – 80 MHz (crit A)
EN 61000-4-8, power frequency magnetic field Enclosure:
1000 A/m 50 Hz
300 A/m 16.7 Hz, 60 Hz, DC (crit A)
EN 61000-4-9, pulsed magnetic field Enclosure, 300 A/m (crit A)
EN-50155, voltage dips and interruption DC power ports:
10 ms, interruption (crit A)
100 ms +- 40 % above/below rated voltage (crit A)
EN 55022, radiated RF emission Enclosure, Class B
FCC part 15, radiated RF emission Enclosure, Class B
EN 55022, conducted emission DC power port & Ethernet ports, Class B
FCC part 15, conducted emission DC power port, Class B
Safety
EN 60950-1, dielectric strength Ethernet ports to other isolated ports, 707 VDC 1 min
Climatic
Temperature, operating –40 to +70ºC (–40 to +158ºF)
Temperature, storage –40 to +70ºC (–40 to +158ºF)
Humidity, operating 5 to 95% relative humidity
Humidity, storage 5 to 95% relative humidity
Enclosure
Enclosure UL 94, Nickel coated zinc, flammability class V-1
Dimensions (W x H x D) 175 x 100 x 53,4 mm (6.88 x 3.93 x 2.10 in)
Weight 1 kg
Degree of protection IP 65 when all ports are protected/connected else IP 40
Cooling Convection
Mounting DIN Rail or wall mounted
Mechanical
IEC 60068-2-6, vibration Random simulated long life, not operating:
Vertical: 7.9 m/s2
Transverse: 7.9 m/s2
Longitudinal: 7.9 m/s2
3 x 5 h
Random functional, operating:
Vertical: 1.0 m/s2
Transverse: 1.0 m/s2
Longitudinal: 1.0 m/s2
3 x 10 min
IEC-60068-2-27, shock Half sine pulses, operating:
Vertical: 50 m/s2
Transverse: 50 m/s2
Longitudinal: 50 m/s2
30 ms, 3 x 6 shocks
Sawtooth, operating:
Vertical: 100 m/s2
Transverse: 100 m/s2
Longitudinal: 100 m/s2
11 ms, 3 x 6 shocks
Interface specifications, power
Rated voltage 24 to 110 VDC
Operating voltage Up to 110 VDC
Rated current 30 mA @ 110 VDC
90 mA @ 24 VDC
Rated frequency DC
Inrush current Max 0.02 A2s @ 24 – 110 VDC
Polarity Reverse polarity protected
Redundant power input No
Isolation to Connections X1 – X8 and to ground, 1500 VAC.
Fault relay belongs to the same isolation group as the power supply lines (fault relay signals are also contained within PWR).
Connection 4 pin male M12 connector with A-code
Connector size M12, recommended cable area 0.5 mm2 recommended (minimum 0.25 mm2), cable dimensions depend on choice of M12 connector
Shielded cable Not required, twisted pair is recommended
Fault relay resistance < 10 Ω
Operating voltage Up to 110 VDC
Interface specifications, 10/100BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s or 100 Mbit/s
Duplex Full or half
Circuit type TNV-1
Transmission range 100 m / 328 ft
Isolation to Other Ethernet ports, 500 VAC
PWR, 1500 VAC
Galvanic connection to None, except for shielded contact to housing
Connection 4-pole M12 female with D-code
Shielded cable Not required, twisted pair is recommended
Conductive housing Nickel plated zinc, metal housings of X1-X8 also connected to the housing
Number of ports 8 Ethernet (X1-X8)