Viper-012 ( 12*TX, M12 ) EN50155

WESTERMO Endüstriyel Yönetilemez 12 Port Fast Ethernet Switcht ( 12×10/100-TX, M12 Konnektörlü )

Viper serisi Endüstriyel Ethernet switchlerin genel özelliklerinden bazıları;
· 8 adet 10 / 100 Mbps rugged M12 konnektör
· Büyük networklerde FRNT ( Fast Recovery of Network Topology ) Ring yedeklemesi ile maksimum 20ms’de alternatif yol yedeklemesi
· SNMP, VLAN, QoS, IGMP Snooping, HoL, STP / RSTP desteği
· Kolay konfügürasyon ve üst seviye diagnostic
· Demiryolu araçları için bir standart olan EN 50155 onaylı
· Geniş çalışma sıcaklık aralığı ( – 40 / + 70 )
· 800.000 saatden fazla MTBF değeri
· IP65 robust çok ince metal kaplama
· Geniş DC enerji besleme aralığı ( 24-110V)
· Hareketli parça ve elektrolitik kapasite içermemektedir.
· Yüksek vibrasyona dayanıklı

Viper-012

Product description
Status Active
Article number 3641-0540
Ports 12 x 10/100BaseTX, M12 contact
1 x USB 2.0 host interface
1 x RS-232, 115.2 kbit/s
Description EN 50155 Routing Switch
Warranty period 5 Years
Standard compliance
Environmental EN 61373:1999, Railway applications – Rolling stock equipment. Shock and vibration tests
IEEE1478:2001, Environmental conditions for transit rail car electronic equipment
EN 50124-1: 2001+A1:2003+A2:2005, Railway applications – Insulation coordination
Fire safety standard CEN 45545-2
Reliability prediction
MTBF, operating 636,000 hours, MIL-C217F2, GB, 25°C
Service life, operating 15 years
EMC (Electromagnetic Compatibility)
EN 61000-6-1 Immunity residential environments
EN 61000-6-2 Immunity industrial environments
EN 61000-6-3 Emission standard for residential, commercial and light-industrial environments.
EN 61000-6-4 Emission industrial environments
EN 55022 +A1 Emission IT equipment
EN 55024 Immunity IT equipment
FCC part 15 Class B
EN 50121-4 Railway signaling and telecommunications apparatus
EN-50121-3-2 Railway applications –Rolling stock – apparatus
EN-50155 Railway applications – Electronic equipment used on rolling stock
IEC 62236-4 Railway signaling and telecommunications apparatus
EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ±6 kV
Air: ±8 kV
EN 61000-4-4, fast transients Power port, ±5 kV
Signal ports, ±5 kV
Earth port, ±1 kV
EN 61000-4-5, surge Power port:
L-E: ±0.5 kV, 12 Ω, 9 μF, 1.2/50 μs
L-L: ±0.5 kV, 2Ω, 18 μF, 1.2/50 μs
L-E: ±2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-L: ±2 kV, 42Ω, 0.5 μF, 1.2/50 μs
L-E: ±8.4 kV, 100 Ω, 0.05/0.1 μs
L-L: ±8.4 kV, 100 Ω, 0.05/0.1 μs
Ethernet ports:
L-E: ±1 kV, 2 Ω L-E: ±2 kV, 42Ω, 0.5 μF
EN 61000-4-8, power frequency magnetic field Enclosure, 300 A/m; 0, 16.7, 50, 60 Hz
EN 61000-4-9, pulsed magnetic field Enclosure, 300 A/m
IEC 61000-4-3, RF field AM modulated Enclosure, 20 V/m @ (80 MHz – 2.7 GHz), 1 kHz sine, 80% AM
EN 61000-4-6, conducted RF immunity Power port, 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet ports, 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port, 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
EN 55022, radiated RF emission Enclosure, class B
Power port, class B
Ethernet ports, class B
FCC part 15, radiated RF emission Enclosure, class B
Safety
EN 60950-1, dielectric strength Power port to all other ports, 1.5 kV ACrms, 50 Hz, 1 min
Ethernet ports to all other ports, 1.5 kV ACrms, 50 Hz, 1 min
Safety EN 60950-1, IT equipment
Climatic
Temperature, operating –40 to +70ºC (–40 to +158ºF)
Temperature, storage –50 to +85°C (–58 to +185°F)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
Enclosure
Enclosure Zinc, fire enclosure.
Dimensions (W x H x D) 175 x 62.5 x 100 mm (6.9 x 2.5 x 3.9 in)
Weight 1.4 kg
Degree of protection IP 65
Cooling Convection
Mounting
Mechanical
IEC 60068-2-6, vibration Non operating long life simulation, 7.9 m/s² (RMS) 5 – 150 Hz
Vibration, random functional Operating, 1 m/s² (RMS) 5 – 150 Hz
IEC-60068-2-27, shock Operating, 5 g, 30 ms
IEC 60068-2-27, bump Operating, 10 g, 11 ms
Interface specifications, power
Operating voltage Rated: 24 to 110 VDC Operating: 24 to 110 VDC ± 30%
Operating for 100 ms: 24 to 110 VDC ±40%
Rated current 350 mA @ 24 V and 90 mA @ 110 V
Rated frequency DC
Inrush current 1 mA²s @ 24V and 6 mA²s @ 110V
Startup current 400 mA
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to 1500 VAC rms to all other
Connection 4 pin male M12 A-coded connector, use Westermo cable
3146-1106 for 1.5 m
3146-1107 for 5 m
Connector size M12, recommended cable area 0.5 mm² recommended (minimum 0.25 mm²), cable dimensions depend on choice of M12 connector
Interface specifications, 10/100BaseTX
Electrical specification IEEE IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range Up to 150 m with CAT5e cable or better
Isolation to Other Ethernet ports, 1500 VAC rms
USB and CON or SRV1 and SRV2, 1500 VAC rms
DC, 1500 VAC rms
Connection 4-pin M12 D-code, auto MDI/MDI-X, use e g Westermo cable
3146-1100 M12-M12 – 1 m
3146-1101 M12-M12 – 5 m
3146-1103 RJ45-M12 – 1 m
3146-1104 RJ45-M12 – 5 m
Shielded cable Not required, but recommended in severe electromagnetic environments
Conductive housing Yes
Number of ports 12
Interface specifications, service
Isolation to Service ports that must not be used:
Ethernet ports, 1500 VAC rms
DC, 1500 VAC rms
No isolation between SRV1 and SRV2